Repair Tips From Japan CS centre

 
Model Block Function Symptoms Cause Repair performed
MZ-R50 #25 Main Board KEy-work of Set Unstable (HOlD indicated when not at HOlD) RB804 Cold Solder Re-solder RB804
MZ-R50 #25 Main Board No Playback l511 Replace l511
MZ-R50 #25 Main Board No Power on Using AC ADP lF901 Cold Solder Re-solder lF901
MZ-R50 #25 Main Board No Playback CN501 Poor Contact Replace CN501
MZ-R50 #25 Main Board Stuck while Using Rechargeable Buttery IC505 Failure Replace IC
MZ-R50 MD Section OP No Playback OP Plastic Cylinder Mounted in Photo Detector Is Cracked Replace OP Block
MZ-R50 #17 Motor Flexible Board No Playback Motor Flexible Board Disconnected Replace Motor Flexible Board
MZ-R50 #25 Power Board No Power & "lOW BAtt" indicated CN805 Delaminated Re-solder CN805
MZ-R50 MD Section OP No Recording OP, laser Excessive Voltage Replace OP Block
MZ-R50 #25 Power Board No Playback Q805 Short-circuit Replace Q805
MZ-R50 #17 JOG SW Unit with Dial Mis-operation of Control Button SW Unit Failure Replace Switch Unit
MZ-R50 #25 Power Board DISPlAy & MODE Button Unavailable SW Board Cold Solder Re-solder
MZ-R50 #25 Power Board No Playback Q805 Short-circuit Replace Q805
MZ-R50 MD Section Holder /Chassis lid Unopened & Disc Remains Stuck Chassis Slide lever is Run Aground lOCK Part of Holder (Set is Greatly Shocked by Dropping etc) Remove Holder from Running Aground after Removing ClV Board & Stepping Motor and then Sliding aside Chassis lever
MZ-R50 Mounted circuit board Main board Playback does not stop after opening the lid. (Spindle Motor Motor remains rotating.) RB804 cold solder Resolder RB804
MZ-R50 Mounted circuit board Main board lid does not open. RB802 cold solder Resolder RB802
MZ-R50 Mounted circuit board Main board Misoperation in JOG dial RB802 cold solder Resolder RB802
MZ-R50 Mounted circuit board Main board Disc Error (No playng back, Rotation of Spindle Motor(ClV) is unlocked and unstable.) RB802 cold solder Resolder RB802
MZ-R50 Mounted circuit board Main board DBB switch does not work. RB805 cold solder Resolder RB805
MZ-R50 Mounted circuit board Main board Stuck at "test Mode" RB806 cold solder Resolder RB806
MZ-R50 Mounted circuit board Main board JOG dial is uncontrollable when pushing the JOG dial. RB806 cold solder Resolder RB806
MZ-R50 Flexible board - Playback is occasionally suspended. (lid unopen. or no recording) MD flexible board is scraped and short-circuited with the main chassis. Replace MD flexible board (or stick protection sheet to the scraped part of the flexible board)